AICAR 50mg – Lyophilized Research Vial
AICAR (acadesine) 50mg research compound, a small-molecule nucleoside analog and not a peptide. Lot PG-6003 reported at >99.80% purity with an identity pass by HPLC-UV/VIS (Vanguard Laboratory). For laboratory research use only.
Test results for this batch
Product details
Frequently asked questions
Store lyophilized vials at -20°C for maximum shelf life up to 24 months. Reconstituted solutions should be refrigerated at 2°C to 8°C and used within 30 days.
Every vial is printed with a batch lot number. You can check the HPLC purity certificate for that lot in the Test Results section above.
Orders placed before 6:00 PM ET, Monday to Friday, ship the same day from our Florida warehouse with full USPS / FedEx tracking.
Best sellers
About AICAR 50mg – Lyophilized Research Vial
AICAR (acadesine, AICA-riboside) is a small-molecule nucleoside analog, not a peptide.[1] Peptide Giants supplies it as a lyophilized powder in a 50 mg vial for laboratory research only. The published lot, PG-6003, was tested by Vanguard Laboratory by HPLC-UV/VIS, and its certificate reports identity, chromatographic purity and quantity.
You can browse every batch report on our lab reports page. Free shipping applies on 5 or more vials or orders over $200.
Specifications
| Compound name | AICAR (PubChem record title: Acadesine; also listed as AICA-riboside)[1] |
|---|---|
| Chemical name | 5-amino-1-[(2R,3R,4S,5R)-3,4-dihydroxy-5-(hydroxymethyl)oxolan-2-yl]imidazole-4-carboxamide[1] |
| Compound class | Nucleoside (adenosine analog). It is not a peptide. |
| Molecular formula | C9H14N4O5[1] |
| Molecular weight | 258.23 g/mol (PubChem value; not measured on the lab report)[1] |
| CAS number | 2627-69-2[1] |
| Form | Lyophilized powder |
| Size | 50 mg per vial |
| Lot number | PG-6003 |
| Purity (lot PG-6003) | >99.80% ± 0.18% (chromatographic purity, HPLC-UV/VIS) |
| Identity (lot PG-6003) | Pass, matches the reference standard (HPLC-UV/VIS); the standard is not named on the report |
| Measured content (lot PG-6003) | 60.66 mg reported against 50 mg labeled (HPLC-UV/VIS) |
| Report date | 1 August 2026 |
| Testing laboratory | Vanguard Laboratory |
The lab data above applies to lot PG-6003 only.
Product details
Overview
AICAR is the ribonucleoside of 5-aminoimidazole-4-carboxamide. PubChem lists it as acadesine and as AICA-riboside, with the formula C9H14N4O5 and a molecular weight of 258.23.[1] It is sold in our catalogue alongside research peptides, but it is a small molecule and has no amino acid sequence.
Published research
A 1995 study reported that incubating rat hepatocytes with AICAR led to accumulation of the monophosphorylated derivative ZMP inside the cells. The authors described ZMP as mimicking both activating effects of AMP on AMP-activated protein kinase (AMPK), without changing cellular ATP, ADP or AMP contents.[2] A 2021 systematic review describes AICAR (written AICAr there) as one of the most commonly used pharmacological modulators of AMPK activity and reviews AMPK-independent effects reported for it.[3]
Purity and quality testing
Lot PG-6003 was tested by Vanguard Laboratory, and the full certificate of analysis for lot PG-6003 is published. The results are summarized below.
| Lot | Laboratory | Report date | Purity | Measured vs labeled | Identity |
|---|---|---|---|---|---|
| PG-6003 | Vanguard Laboratory | 1 Aug 2026 | >99.80% ± 0.18% | 60.66 mg vs 50 mg | Pass (reference standard) |
What the chromatogram shows
The printed chromatogram is headed DAD1 A with the signal labeled 214.4. It shows one dominant peak, labeled AICAR, at about 2.774 minutes with a printed area of 5919.41. No other peaks are labeled or given an area, and the baseline is otherwise flat. The report does not define how the >99.80% ± 0.18% figure was calculated from the chromatogram.
What the certificate says about the laboratory
The certificate carries an ISO/IEC 17025:2017 accreditation mark and refers to an A2LA certificate for the list of accredited tests. It does not say which tests the accreditation covers. It also states that the results relate only to the portion of the sample tested, and that the laboratory did not observe the sample selection and cannot confirm the authenticity of the sample or its representativeness of the lot.
What the report does not cover
The identity result is a comparison with a reference standard by HPLC-UV/VIS, and the standard is not named. The report has no mass spectrum or NMR result, and no heavy metals, residual solvents, water content, endotoxin or sterility testing. The measured quantity of 60.66 mg is about 21.3% above the 50 mg label (our calculation), and the report does not say why. It describes one tested lot and does not cover every vial.
How to read a lab report
- Check the lot number and report date. The lot shown here is PG-6003, and it should match your vial label.
- Find the identity, purity and quantity rows and the method listed for each. Here all three use HPLC-UV/VIS.
- Look at the chromatogram for one dominant peak and for any other labeled peaks.
- Read the laboratory statement about what the sample represents, and treat the result as describing that lot only.
Form, preparation and storage
Why researchers order from Peptide Giants
Reliable work depends on knowing what is in the vial. A rounded “99%+” tells you little. We publish the batch result and the measured content instead.
Frequently asked questions about AICAR Lyophilized Research Compound
What is AICAR?
AICAR (acadesine, AICA-riboside) is a small-molecule nucleoside analog with the formula C9H14N4O5.[1] It is sold here as a lyophilized powder for laboratory research only.
Is AICAR a peptide?
No. AICAR is a nucleoside analog, a small molecule with no amino acid sequence. It is sold alongside our research peptides.[1]
What other names does AICAR go by?
PubChem lists the record title acadesine and the synonyms AICA-riboside and AICA riboside.[1]
What are the formula, molecular weight and CAS number?
C9H14N4O5, 258.23 g/mol and CAS 2627-69-2, as listed by PubChem.[1] These are reference values, not lab measurements.
What do the published studies report?
A 1995 study in rat hepatocytes reported that AICAR led to intracellular accumulation of the monophosphorylated derivative ZMP, which mimicked the activating effects of AMP on AMPK.[2] A 2021 systematic review covers AMPK-independent effects reported for AICAR.[3] This page makes no claims about effects or use.
What size is sold?
A 50 mg vial of lyophilized powder.
What purity was tested?
Lot PG-6003 was reported at >99.80% ± 0.18% chromatographic purity by HPLC-UV/VIS at Vanguard Laboratory, with a report date of 1 August 2026.
How was purity measured?
By HPLC-UV/VIS. The chromatogram shows one dominant peak labeled AICAR at about 2.774 minutes, and no other labeled peaks. The report does not define how the percentage was calculated.
Does the report confirm identity?
The certificate lists an identity result of Pass, matching the reference standard, by HPLC-UV/VIS. The reference standard is not named, and the report has no mass spectrum or NMR result.
How does the measured content compare with the label?
The certificate lists a quantity of 60.66 mg against a 50 mg label, about 21.3% above (our calculation).
Why does the measured quantity exceed the label?
The certificate does not explain it, and we have not published a reason.
Is the testing laboratory accredited?
The certificate carries an ISO/IEC 17025:2017 accreditation mark and refers to an A2LA certificate for the accredited tests. It does not say which tests the accreditation covers.
Does a report cover every vial?
No. The laboratory states that results relate only to the portion of the sample tested and that it cannot confirm the representativeness of the lot.
Can I see the lab report before buying?
Yes. The lot PG-6003 certificate is linked on this page, and every published batch report is on our lab reports page.
References
- National Center for Biotechnology Information. PubChem Compound record CID 17513, Acadesine (AICA-riboside; C9H14N4O5; CAS 2627-69-2). PubChem 17513
- Corton JM, Gillespie JG, Hawley SA, et al. 5-aminoimidazole-4-carboxamide ribonucleoside. A specific method for activating AMP-activated protein kinase in intact cells? Eur J Biochem. 1995;229(2):558-565. PubMed
- Višnjić D, Lalić H, Dembitz V, et al. AICAr, a Widely Used AMPK Activator with Important AMPK-Independent Effects: A Systematic Review. Cells. 2021;10(5):1095. PubMed
Content last reviewed 28 November 2026. Formula and mass values are PubChem reference values and our calculations, not measurements from the lab report.
Research background
Extensively researched across peer-reviewed literature for cellular mechanisms, binding affinity, and biochemical pathways in laboratory models.
Quality and analytical standard
Each batch is tested by Vanguard Laboratory, a third-party analytical lab. Check the lot number on your vial against the test results and COA on this page.
Customer reviews
Third time ordering. Lyophilized powder reconstitutes crystal clear with zero residue. Fast domestic shipping with tracking provided right away. You can trust Peptide Giants.
Dispatched the same afternoon from Tampa and arrived on my doorstep two days later. The insulated protective packaging ensured vials were completely intact.
Reached out on WhatsApp before buying to confirm batch expiry dates. Got a friendly response within 10 minutes. Research results have been spot-on.
No customs delays since it ships straight out of Florida. Clean cakes, sterile crimps, and rapid delivery every single time.